The air at City Honors, right now.
Two monitors watch the same school from both sides of the wall: one in the hallway, one outside the front doors. A third sits in Room 301, where it also counts the carbon dioxide a full class breathes out, and a fourth is in Room 303. Below the live readings is every reading they have taken, ready to explore.
Explore the data
Hover for values · drag to zoomFine particles (PM2.5)
Shaded bands are night. Filled dots mark each monitor’s highest reading in view, hollow dots the lowest. Drag across the chart to zoom in; double-click to zoom back out.
In this view
| Monitor | Latest | Average | Low | High |
|---|
Highest moments
Click one to zoom in on it.
PM2.5 here is the US EPA corrected value (Barkjohn et al.), the number to compare with a regulatory monitor, and the air quality index uses the EPA’s 2024 breakpoints. On the PurpleAirs, temperature and humidity are measured inside the monitor case, so temperature reads a few degrees warm. PM1 and PM10 are laser estimates the EPA does not validate. Longer spans are shown as 30-minute or 2-hour averages so the page stays fast; the high points still use the highest single reading.
About the Room 301 monitor
The Room 301 readings come from a PocketLab Air, a classroom sensor built for teaching. It is not the same kind of instrument as the two PurpleAirs, and its numbers are less reliable.
- Particles in whole numbers only. It reports PM1, PM2.5 and PM10 as whole micrograms (3, 4, 5), never 3.4. In clean air that is a big share of the reading, so small changes are lost.
- A noisier line. Its particle line jumps up and down more than the PurpleAirs’. Part of that is the whole numbers: when the air sits between 3 and 4, the reading flips back and forth between them. It records a reading every minute, so the chart draws each point as the average of its last 10 readings (10 minutes) to calm the flicker. Look at the overall trend, not each wiggle.
- One laser, not two. Each PurpleAir has two particle lasers that check each other. The PocketLab has one, so a bad reading has nothing to catch it.
- A borrowed correction. The EPA correction was built and tested on PurpleAirs. We apply it to the PocketLab so the numbers line up, but it was never tested on this sensor.
- Carbon dioxide can drift. CO₂ is the PocketLab’s best measure and the only one the PurpleAirs lack. Sensors like it slowly drift, so compare today with last week more than with a textbook number.
- Gaps. It sends its data over Bluetooth to a small bridge computer. If that link drops, the line on the chart has a gap.